CueStation is a family of wall stations for use with CueServer. There are three CueStation series (Insite, Mystique, and Ultra) that include
various touchscreens and button stations. Our button stations are available in many hundreds of semi-custom configurations, allowing
choices of button style, color, engraving, LED color, and network technology.
The Mystique series features 1/2" (13mm) square buttons available in 1, 2, 3, 4 or 8 button configurations. This station provides a soft touch
and allows the keycaps to be engraved. Each button has an indicator LED next to its top-right or top-left corner (depending on which side of
the station the button is located). Individual key caps may be engraved or the top of each column may be engraved on the cover plate.
There are three types Passive, Digital 2-Wire and Digital 5-Wire. Depending on type chosen, may require additional hub to connect to the
Cueserver. The 2-Wire network is recommended primarily for retrofit (where the project is limited by the existing, typically 2 conductor, wiring)
or very small new installations. It is strongly recommended to use the 5-Wire CueStation network for all new installations. Colors available are
black, white, ivory, and almond.
Features:
- Four Designer Colors (White, Black, Almond, Ivory)
- Stylish Flushplates Included
- Passive Compatible
- Single-color LEDs on passive stations with LEDS
- Customized Engraving Available
- Multi-Gang Compatiblity
- Short Lead Times
Passive CueStations simply provide dry-contact switch closures for direct connection to devices that are expecting a contact closure to
activate an event. There is a single terminal for each switch plus an extra terminal which is the "switch common" on the back of the station.
For example, on a six button station, seven conductors would be needed (the six switches, plus one common).
The Passive CueStation is designed to be directly connected to the contact closure inputs and digital output ports of a CueServer processor,
however, these stations can be used in a wide variety of custom applications as well.
The LED indicators on a Passive station are wired similarly. Each LED has a single terminal on the back of the station, plus an additional
terminal for the LED common. By default, the LEDs are wired with all of the positive (+) leads tied together as the LED common and the
negative (-) leads are all separately wired to the LED terminals. This allows the LEDs to be controlled by a switched-to-ground connection for
each LED. The station includes LED current limiting resistors normally set up for 5VDC operation. If you need a different LED polarity or
operation voltage, please contact us.
Specifications: Series: Mystique ■ Buttons: 8 ■ Indicators: No LEDs ■ Wiring: 9 conductors ■
Connections: 1 x 9 terminal wire blocks ■ Mounting: single gang box 3.05" x 2" x 1.29" deep ■ Size: 4.87" x 3.12" x 0.83" ■ Weight: 4 kgs/2 lbs ■ Color: Black
Country Of Origin: United States
Unspsc: 39112402
U.S.Tariff#: 8537.10.9060
Warranty: 1 Year Limited
Color: Black